[ns-bug-011] When creating a master file from a rough sketch, devices may not be included in the master file if the horizontal axis distances between devices are close. |
Increase horizontal axis distance between devices. |
2.3.4 |
[ns-bug-002] If "Way Points" between Areas are not interconnected, the generation of "Master Data" will fail. |
Move unconnected "Way Point" between Areas up/down the "Area". |
2.3.4 |
[ns-bug-012] Layer 2 Diagram generation fails. |
Use version 2.3.1 or earlier |
2.3.3(b) |
[ns-bug-010] When synchronizing L1 per area file to master file(3-1), VPN settings in L3 sheet of master file are deleted. |
Copy the VPN settings from the backup master file and resynchronize. |
2.2.3(b) |
[ns-bug-009] Failure to generate a master file for a rough sketch with no wire connections |
Creating dummy wires. |
2.2.3(b) |
[ns-bug-008] Master file creation may fail depending on vertical way point placement. |
None |
2.2.1(b) |
[ns-bug-007] VPN is not filled in the diagram when "Yes" is selected in the dialog after generating the VPN Diagram. |
Select "No" in the dialog |
2.2.1(a) |
[ns-bug-006] A bug that could cause duplicate rows to be output in the IP address table |
None |
2.1.1(c) |
[ns-bug-005] DEVICE file generation fails when using python v3.12.x |
Use Python version 3.11.7 or lower. |
This bug has been fixed in 2.1.1(b) to the extent that it does not stop with an error. However, since it is caused by a bug in openpyxl, update openpyxl to 3.1.3 or later as soon as possible. |
[ns-bug-004] Caused file generation to fail in certain Windows environments |
None |
2.1.1(a) |
[ns-bug-003] On Mac OS, file cannot be opened from the dialog after drawing a diagram |
ignore dialogs |
2.1.1 |
[ns-bug-001] If a "way point" that does not exist above or below the leftmost "Area" exists in the right "Area", the generation of "Master Data" will fail. |
Move unconnected "Way Point" between "Area" up/down the "Area". |
1.12 |