Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Some notes and examples are not extracted #163

Open
skalee opened this issue Mar 17, 2021 · 2 comments
Open

Some notes and examples are not extracted #163

skalee opened this issue Mar 17, 2021 · 2 comments
Assignees
Labels
bug Something isn't working

Comments

@skalee
Copy link
Contributor

skalee commented Mar 17, 2021

103-01-11:

  notes:
  - |-
    Examples:



    * Legendre polynomials P constitute a system of orthogonal functions on the interval stem:[- 1 , + 1] because stem:[int_( - 1)^( + 1) P_k ( x ) P_l ( x ) d x = 0] for any integers stem:[k != l].

    * Laguerre polynomials L constitute a system of orthogonal functions on the interval stem:[0 , + oo] with the weight stem:[e x p ( - x )] because stem:[int_( 0)^( + oo) L_k ( x ) L_l ( x ) exp ( - x ) d x = 0] for any integers stem:[k != l].

    * Trigonometric functions sine and cosine constitute a system of orthogonal functions on the interval stem:[0 , 2 pi] because stem:[int_( 0)^( 2 pi) sin ( k x ) sin ( l x ) d x = 0] and stem:[int_( 0)^( 2 pi) cos ( k x ) cos ( l x ) d x = 0] for any integers stem:[k != l], and stem:[int_( 0)^( 2 pi) sin ( k x ) cos ( l x ) d x = 0] for any integer stem:[k] and stem:[l].

447-01-49:

  examples:
  - |-
    Distance protection equipment, phase comparison protection equipment.

    Note 1 to entry: "Protection equipment" is part of a {{"protection system", IEV:448-11-04}}. For example, phase comparison equipment is part of one line-end of a phase comparison protection system.

447-03-02:

  examples:
  - |-
    * Current, for {{current relay, IEV:447-01-27}}, {{thermal electric relay, IEV:447-01-36}} and ({{differential relay, IEV:447-01-40}});* voltage, for {{voltage relay, IEV:447-01-28}}, {{frequency relay, IEV:447-01-29}}, {{volt per hertz relay, IEV:447-01-47}} and {{synchronizing relay, IEV:447-01-45}};* voltage and current, for {{impedance relay, IEV:447-01-30}}, {{directional relay, IEV:447-01-41}} and {{power relay, IEV:447-01-42}}.

    Note 1 to entry: The {{input energizing quantity, IEV:447-03-02}} can be applied to a {{measuring relay, IEV:447-01-02}} or {{protection equipment, IEV:447-01-49}} either by hardwire from {{instrument transformers, IEV:321-01-01}} or as a data packet over communication ports using an appropriate data communication protocol, such as IEC 61850-9-2.

    Note 2 to entry: In IEC 60050-447:2010, "characteristic energizing quantity" was numbered 447-03-03, as a substitute of {{"input energising quantity", IEV:447-03-02}}, and "input energising quantity" was provisionally defined for the existing IEC 60255 series standards. However, "input energizing quantity" is internationally accepted.
  entry_status: valid

701-01-32:

  examples:
  - |-
    Sound broadcasting, television broadcasting, {{broadcast videography, IEV:701-01-18}}, distribution of time signals and navigational warnings, distribution of news from press agencies.

    Note 1  to entry: Broadcasting is a {{point-to-area communication, IEV:713-02-16}}.
@skalee skalee added the bug Something isn't working label Mar 17, 2021
@skalee skalee self-assigned this Mar 17, 2021
@skalee
Copy link
Contributor Author

skalee commented Mar 19, 2021

@ronaldtse Could you confirm that only concepts in English or French have notes and examples?

@ronaldtse
Copy link
Member

Yes confirmed.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Something isn't working
Projects
None yet
Development

No branches or pull requests

2 participants